Custom Packed / Micropacked Column Request Form Logo
  • Custom Packed / Micropacked Column Request Form

    Please submit a new request for each unique column configuration.
  • Contact Information

  • Number of Columns

  • Please specify how many columns of a single configuration you would like to have quoted.

    Note: a new form submission must be placed for each column configuration being requested.

  • Tubing Length

  • Tubing Diameter

  • Tubing Material

  • Welded Tubing Reducers

  • Image-273
  • NOTE: Welded tubing reducers can only be used for 1/8" ID tubing going to 1/16" ID tubing. These welded tubing reducers can be used instead of using a reducing union.

  • Fittings Kit - 1/4" OD Columns

  • Kit_1S
  • Fittings Kit 2S
  • Fittings Kit B2
  • Fittings Kit B2
  • Fittings Kit E
  • Fittings Kit F
  • Fittings Kit G
  • Fittings Kit - 1/16" OD Columns

  • Image-433
  • Fittings Kit - 1/8" OD Columns

  • Kit A
  • Kit B
  • Kit C
  • Kit D
  • Kit VNICKEL
  • Kit VSS
  • Fittings Kit - 3/16" OD Columns

  • Fittings Kit 2S
  • Fittings Kit F
  • Inlet & Outlet Packing

  • NOTE: Column voids are included in the total length of the column unless otherwise specified.

  • Image-89
  • Please leave a   *   inch void in the inlet for on-column injection.
    Minimum void length is 1 inch.

  • Please leave a   *   inch void in the outlet.
    Minimum void length is 1 inch.

  • End Plugs - 1/8" OD Columns

  • Image-276
  • Image-278
  • Image-279
  • Frits can only be inserted to the depth shown.

  • Image-396
  • End Plugs - 1/8" OD Columns

  • Image-395
  • End Plugs - 1/4" OD Columns

  • Image-315
  • End Plugs - 0.74 mm OD Columns

  • Image-310
  • Image-311
  • Braided wire plug will be located within the crimped segment of tubing

  • End Plugs - 0.95 mm OD Columns

  • Image-305
  • Image-306
  • Braided wire plug will be located within the crimped segment of tubing

  • End Plugs - 3/16" OD Columns

  • Image-317
  • End Plugs - 1/16" OD Columns

  • Image-298
  • Image-297
  • Braided wire plug will be located within the crimped segment of tubing

  • Image-299
  • Image-301
  • Image-300
  • Frits can only be inserted to the depth shown.

  • Number of Liquid Phases

  • Columns may have up to three liquid phases.

  • Available Liquid Phases

  • Remember to specify the coating percentage for each one.
    Coatings >15% may incur additional charges.

     

    Note: The solid support of your packed column determines how much liquid phase can be applied (max liquid phase loading). Please review the table below to determine the maximum liquid phase loading for each solid support. Requesting a liquid phase loading above the maximum will delay order processing as Restek will need to contact you for changes to your order before providing a quote.

     

    Max Liquid Phase Loading Solid Support
    5% ResSil C
    3% ResSil B
    1% CarboBlack C
    10% CarboBlack B
    15% Hayesep A, B, C, D, DB, N, PAW, Q, QAW, S, T
    15% PoraPak N, P, PAW, PS, Q, QS, R, S, T
    10% Chromosorb G
    10% Chromosorb GAW
    10% Chromosorb GAWDMDCS
    10% Chromosorb GHP
    10% Chromosorb GNAW
    0% N-Octane on Res-Sil C
    0% OPN on Res-Sil C
    0% Molsieve 5A, 13X
    30% All other Solid Supports not listed above

     

  •  
  •  
  •  
  • Solid Support

  • Mesh

  • Mesh Size Conversions

  • Information on mesh size micron-conversion

    Mesh

    Microns

    20 850
    25 710
    30 600
    35 500
    40 425
    45 355
    50 300
    60 250
    70 212
    80 180
    100 150
    120 125
    140 106
    170 90
    200 75
    230 63
    270 53

    Example: 80/100 mesh = particle sizes between 180 and 150 microns.

  • Configurations

  • At Restek, we can configure your column to meet your specific requirements. Whether you prefer a standard configuration or require something customized, we have got you covered. We provide several standard configurations that are compatible with popular instruments, ensuring that your column fits seamlessly into your workflow. If you require a more unique configuration, we offer a variety of special configurations that allow you to define your own dimensions. For an overview of all the configuration styles we offer at Restek, please click here.

     

  • Configurations

  • At Restek, we can configure your column to meet your specific requirements. Whether you prefer a standard configuration or require something customized, we have got you covered. We provide several standard configurations that are compatible with popular instruments, ensuring that your column fits seamlessly into your workflow. If you require a more unique configuration, we offer a variety of special configurations that allow you to define your own dimensions. For an overview of all the configuration styles we offer at Restek, please click here.

     

  • Standard Configuration Style

  • Image-357
  • Image-358
  • Image-359
  • Image-360
  • Image-361
  • Image-362
  • Image-363
  • Image-364
  • Image-367
  • Image-368
  • Image-366
  • Image-369
  • Image-375
  • Image-373
  • Image-372
  • Image-374
  • Image-370
  • Image-406
  • GOW MAC 836
  • If your desired column configuration measurements do not fall within specifications for a standard configuration, a custom configuration must be used instead.

    To view all standard configurations, please click here.

  • Custom Configuration Styles

  • Image-337
  •  
  • Image-342
  •  
  • Image-343
  •  
  • Image-340
  •  
  • Image-339
  •  
  • Image-338
  •  
  • Image-347
  •  
  • Image-348
  •  
  • Image-349
  •  
  • Image-351
  •  
  • Image-352
  •  
  • Image-353
  •  
  • Image-354
  •  
  • Image-355
  •  
  • Image-356
  •  
  • Prioritization Note: Figures 1-15 may be used to specify measurements for a packed column to be made in a custom configuration. We will manufacture the column to hit all the specifications to the best of our ability prioritizing specifications in the following order: Arm span (S), arm length (X,Y), coil size (B), then coil height (A). There is no guarantee that all specifications will be met for a custom configuration. 

    To view all custom configurations, please click here.

  • Standard Configuration for Micropacked Columns

  • Image-365
  • Conditioning

  • Comments and Review

  • If your packed column requires an option not specified on this form, please contact Restek for a quote.

  • Please review your quote carefully to ensure what you selected fits your needs. If any changes need to be made to your quote, please contact us. Custom packed columns are not returnable or refundable and are not guaranteed for performance.

  • Should be Empty: