Please specify how many columns of a single configuration you would like to have quoted.
Note: a new form submission must be placed for each column configuration being requested.
NOTE: Welded tubing reducers can only be used for 1/8" ID tubing going to 1/16" ID tubing. These welded tubing reducers can be used instead of using a reducing union.
NOTE: Column voids are included in the total length of the column unless otherwise specified.
Please leave a example: 1/4* inch void in the inlet for on-column injection.
Please leave a example: 1/4* inch void in the outlet.
Frits can only be inserted to the depth shown.
Braided wire plug will be located within the crimped segment of tubing
Columns may have up to three liquid phases.
Remember to specify the coating percentage for each one.Coatings >15% may incur additional charges.
Mesh
Microns
Example: 80/100 mesh = particle sizes between 180 and 150 microns.
At Restek, we can configure your column to meet your specific requirements. Whether you prefer a standard configuration or require something customized, we have got you covered. We provide several standard configurations that are compatible with popular instruments, ensuring that your column fits seamlessly into your workflow. If you require a more unique configuration, we offer a variety of special configurations that allow you to define your own dimensions. For an overview of all the configuration styles we offer at Restek, please click here.
If your desired column configuration measurements do not fall within specifications for a standard configuration, a custom configuration must be used instead.
To view all standard configurations, please click here.
Prioritization Note: Figures 1-15 may be used to specify measurements for a packed column to be made in a custom configuration. We will manufacture the column to hit all the specifications to the best of our ability prioritizing specifications in the following order: Arm span (S), arm length (X,Y), coil size (B), then coil height (A). There is no guarantee that all specifications will be met for a custom configuration.
To view all custom configurations, please click here.
If your packed column requires an option not specified on this form, please contact Restek for a quote.
Please review your quote carefully to ensure what you selected fits your needs. If any changes need to be made to your quote, please contact us. Custom packed columns are not returnable or refundable and are not guaranteed for performance.